Wet Drum Magnetic Seaparator CR 9/ P2L
Magnetite recovery in coal preparation plants
|
Size |
9/6 |
9/9 |
9/12 |
9/15 |
9/18 |
9/21 |
9/24 |
9/27 |
9/30 |
9/36 |
|
Pulp Volume Capacity m³/ |
|
|
|
|
|
|
|
|
|
|
|
Maximum |
96 |
144 |
196 |
240 |
288 |
336 |
384 |
432 |
480 |
576 |
|
Recommended ‘primary’ duty |
84 |
126 |
168 |
210 |
252 |
294 |
336 |
378 |
420 |
504 |
|
Recommended ‘secondary’ duty |
60 |
90 |
120 |
150 |
180 |
210 |
240 |
270 |
300 |
360 |
|
Magnetite Dry Solids t/h @ Recommended Pulp Volume |
|
|
|
|
|
|
||||
|
Maximum (250 g/l) |
21 |
32 |
42 |
53 |
63 |
74 |
87 |
95 |
105 |
126 |
|
Recommended (200 g/l) |
17 |
25 |
34 |
42 |
50 |
59 |
67 |
76 |
84 |
101 |
For ‘sizing’ double drum (Primary-Secondary combination); use maximum pulp volume for feed rate to primary drum.
For best recovery on secondary drum reduce the pulp volume to that recommended for secondary duty – effluent overflow compartment on tank allows this.
Recovery efficiency at recommended ratings
Valid for typical magnetite size distribution:
95 to < 53 Microns
90% < 45 Microns
30% < 10 Microns
Primary Duty = 99.9% - Valid for up to 50% non-mags solids in feed.
Secondary Duty = 90%
Magnetite Concentrate Density
Magnetite Recovered at 2.3 r.d.